MicroGrid Expanded Metal Foil- Expanded Metal - Expanded Metal Mesh - Expanded Metal Grid  - Dexmet Corporation

MicroGrid®
Precision-Expanded Foils


Samples of Product Resistivity Ranges


SWD milli-ohms for .007 strand
Metal OA: Aluminum
0.002 to .005
Copper
0.002 to .005
Nickel
0.002 to .005
Stainless Steel
0.002 to .005
Config        
0.05 1.3 to 3.4 1 to 2.4 5.2 to 13.2 40.6 to 102.8
0.077 2.1 to 6 1. 5 to 4.4 8.3 to 24.2 64.5 to 189.3
0.1 3 to 8.2 2.2 to 6 12.1 to 32.7 94.5 to 255.4
0.125 3.8 to 10.5 2.8 to 7.5 15.2 to 41.3 118.8 to 322


LWD milli-ohms for .007 strand
Metal OA: Aluminum
0.002 to .005
Copper
0.002 to .005
Nickel 0.002 to .005
Stainless Steel
0.002 to .005
Config        
0.05 .6 to 1.4 .4 to 1 2.3 to 5.5 18 to 43.3
0.077 .7 to 1.9 .5 to 1.4 2.5 to 7.6 19.8 to 59.1
0.1 .8 to 2.1 .6 to 1.5 3.2 to 8.3 25 to 58.8
0.125 1 to 2.5 .7 to 1.8 3.8 to 37.7 29.6 to 77.4

Notes on resistivity:
Increasing the strand width will decrease resistivity for both the LWD and SWD direction of mesh.

Increasing the original metal thickness will decrease resistivity for both the LWD and SWD direction of mesh. Decreasing the strand width will increase resistivity for both the LWD and SWD direction of mesh. Decreasing the original metal thickness will Increase resistivity for both the LWD and SWD direction of mesh. Pulling a product will decrease the resistivity in the SWD direction and increase the resistivity in LWD direction.



Dexmet Corporation
Naugatuck, CT 06770 - 203.723.1514
products@dexmet.com

Home - ©Dexmet Corporation