Microgrid® – Answers to Frequently Asked Questions

Question:

What variables can be changed to increase or decrease the weight per unit area of a given product?

Answer:

Increases or decreases in the base metal thickness and/or strand width are two of the most frequently used methods of accomplishing this goal… especially when the appropriate metal and mesh size have already been identified. Please let us know if the weight is important in the final application and we will work with you to define the other variables.

Open Area vs Strand

Question:

I would like to make a change in the amount of surface area per unit area.How can that be accomplished?

Answer:

Let’s say for instance, you would like to increase the amount of surface area. An increase in the strand width will increase the surface area. Choosing a smaller mesh size or LWD will make a more significant change as well.

Question:

The sample I have is 5 Al 10-125. The 125-mesh size is what I need for my process but I would like to increase the percentage of open area slightly. What can you do?

Answer:

The first variable that we would change is the strand width. A decrease in the strand from 10 mils down to 7 mils will increase the open area approximately 10%, assuming the SWD stays constant.

Question:

I am interested in Dexmet MicroGrid® for its superior electrical, shielding or heat transfer properties. What variables can be changed to increase the conductivity across the width as well as in the roll direction?

Answer:

An increase in the base metal thickness and/or strand width will result in an increase in the conductivity in both directions. Altering the SWD or LWD can make more subtle changes. In general, the conductivity will be greater across the width than in the roll direction by about 2 to 1.

Question:

What if I need a product with conductivity or resistance that is equal in both directions?

Answer:

You may need a “Distex Brick”” product. The controlled stretch will decrease the LWD and increase the SWD. This change in the geometry of the diamond will result in the desired characteristics.

Question:

How do I order Dexmet MicroGrid® precision expanded foils?

Answer:

MicroGrid® is an OEM product, engineered, configured and custom manufactured to stringent specifications developed in unison with our customers. But, once we have determined the product code, all we need is the desired width and quantity. The quantity is always determined by length of the material required as opposed to weight.

Contact Us

Phone: (800) 714-8736
Fax: (203) 294-7899

sales@dexmet.com

22 Barnes Industrial Rd. So.
Wallingford, CT 06492
United States of America

Events Calendar

SAMPE Seattle 2017

May 23-24, 2017
Washington State Convention Center,
Seattle, Washington – Booth# E42
Information on SAMPE Seattle 2017

EMC 2017

April  August 8-10, 2017
Gaylord National Resort & Convention Center,
National Harbor, MD – Booth# 816
Information on EMC 2017

View all upcoming events